Safety & compliance

Directives, voltage levels and operating limits for each product, taken from the product specifications.

FÖGE ionizing and charging products operate with high voltage (up to 30 kV). Installation, commissioning, maintenance and servicing must be carried out by qualified personnel in accordance with the operating manual of the product.

Static electricity solutions

ProductVoltageEMCElectrical safetyOperating temperatureMax. humidity
SE-ACB-55
Compact AC Antistatic Bar – 5.5 kV
5.5 kV2014/30/EU — EMC Directive2014/35/EU — Low Voltage DirectiveMax. 60 °C70 % rH, non-condensing
SE-ACB-80
High Power AC Antistatic Bar – 8 kV
8 kV2014/30/EU — EMC Directive2014/35/EU — Low Voltage DirectiveMax. 60 °C70 % rH, non-condensing
SE-ACA
Long Range AC Antistatic Bar with Air
5.5 kV (SE-ACA-55) · 8 kV (SE-ACA-80)2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive——
SE-DCB-90
Pulsed DC Antistatic Bar – 9 kV
9 kV pulsed DC2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive0 – 50 °C70 % rH, non-condensing
SE-DCB-110
Pulsed DC Antistatic Bar – 11 kV
11 kV pulsed DC2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive0 – 50 °C70 % rH, non-condensing
SE-DCA-110
Pulsed DC Antistatic Bar with Compressed Air – 11 kV
11 kV pulsed DC2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive0 – 50 °C70 % rH, non-condensing
SE-BLC-F-75-C
Compact Antistatic Blower – Pulsed DC
Pulsed DC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive0 – 50 °C70 % rH
SE-BLA
Multi Fan AC Blower Static Eliminator
AC — high voltage, shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive——
SE-BLL
Laminar Air Blower Ionizer
Pulsed DC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive0 – 50 °C70 % rH
SE-SGB-30
Static Generation Bar – 30 kV
Up to 30 kV DC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive——
SE-ACG
Antistatic Airgun
5.5 kV AC — shockless — ESD compliant2014/30/EU — EMC Directive2014/35/EU — Low Voltage DirectiveMax. 60 °C70 % rH, non-condensing
SE-ACS-55-50
Compact Antistatic Spot Nozzle
5.5 kV AC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage DirectiveMax. 60 °C70 % rH, non-condensing
SE-ACIN-55
AC Inline Air Ionizer
5.5 kV AC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive0 – 50 °C70 % rH, non-condensing
SE-HSIN-35-SN-C
High Speed Air Ionizer — Standard Nozzle
—2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive——
SE-ARN-80
Ionizing Ring – 8 kV
8 kV AC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage DirectiveMax. 60 °C70 % rH, non-condensing
SE-ACN
Nozzle AC Antistatic Bar
High voltage AC — shockless2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive——
SE-DCN-110
Pulsed DC Nozzle Antistatic Bar
—2014/30/EU — EMC Directive2014/35/EU — Low Voltage Directive——
SE-PAC
AC High Voltage Power Unit
—2014/30/EU — EMC Directive2014/35/EU — Low Voltage DirectiveMax. 50 °C—
SE-SFM-030
Static Electric Fieldmeter
————70 % rH, non-condensing max.
SE-CLEAN
Antistatic Products Maintenance Kit
—————

LED lights for machine vision

ProductSupply voltageEMCDegree of protection
VL-BAR
Compact Bar Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-BAL
Long Bar Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50
VL-RGF
Direct Ring Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-BLC
High Intensity Compact Backlight
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-BLA
Large Area Backlight
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-FLD
Large Area Flat Dome Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-BLL
Bar Backlight for Line Scan
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50
VL-DOM
Dome Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50
VL-TNL
Tunnel Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-COX
Coaxial Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50 (IP67 on request)
VL-DFF
Dark Field Light
24 V DC2014/30/EU — EMC Directive (EN IEC 55015:2019+A11:2020, IEC 61547:2020)IP50

"—" means the value is not yet confirmed in the product data. Ask FÖGE for the current datasheet and declaration of conformity.

General safety notes

  • Connect ionizing bars, nozzles and airguns only to the power unit specified for them (e.g. SE-PAC-55 for 5.5 kV products, SE-PAC-80 for 8 kV products). Mismatched units can reduce performance or damage the equipment.
  • Disconnect the power supply before cleaning emitter pins or performing maintenance.
  • Use only dry, filtered compressed air for air-assisted products; oil and moisture reduce ionization efficiency and can damage emitter pins.
  • Operate within the specified temperature and humidity limits.
  • Do not operate in potentially explosive atmospheres or near flammable gases, vapours or dust. None of the products on this site is ATEX-certified.
  • For electrostatic charging (SE-SGB-30), the substrate beneath the material must be earthed as specified in the operating manual.

Documents

Datasheets, instruction manuals and dimensional drawings can be downloaded on each product page. Declarations of conformity are available on request: contact FÖGE.